835959-UIM-B-0413
R-410A OUTDOOR SPLIT-SYSTEM
HEAT PUMP
MODELS: 14.5 SEER - YHJF/THJF/THGF60
5 TONS – 1 PHASE
INSTALLATION MANUAL
®
LIST OF SECTIONS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
TXV INSTALLATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SYSTEM START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
INSTRUCTING THE OWNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
LIST OF FIGURES
Typical Installation with Required Clearances . . . . . . . . . . . . . . . . . . .2
Tubing Hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Underground Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Heat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Outdoor Unit Control Box - 14.5 SEER 60 Only . . . . . . . . . . . . . . . . . .5
Thermostat Wiring – Two-Stage Heat Pump -
Variable Speed Air Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Thermostat Wiring – Two-Stage Heat Pump -
Variable Speed Air Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CFM Selection Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Heat Pump Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Wiring Diagram - Single Phase - 14.5 SEER - 5 Ton . . . . . . . . . . . . 10
LIST OF TABLES
R-410A Saturation Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
SECTION I: GENERAL
The outdoor units are designed to be connected to a matching indoor
coil with sweat connect lines. Sweat connect units are factory charged
with refrigerant for a matching indoor coil plus 15 feet of field supplied
lines.
Matching indoor coils are available with a thermal expansion valve or
an orifice liquid feed sized for the most common usage. The orifice size
and/or refrigerant charge may need to be changed for some indoor-out-
door unit combinations, elevation differences, or total line lengths. Refer
to Application Data covering “General Piping Recommendations and
Refrigerant Line Length” (Part Number 036-61920-001).
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury
.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury
.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury
. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
INSPECTION
As soon as a unit is received, it should be inspected for possible dam-
age during transit. If damage is evident, the extent of the damage
should be noted on the carrier’s delivery receipt. A separate request for
inspection by the carrier’s agent should be made in writing. See Local
Distributor for more information.
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service, or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer, or service agency.
This product must be installed in strict compliance with the
enclosed installation instructions and any applicable local, state,
and national codes including, but not limited to building, electrical,
and mechanical codes.
Vedere la pagina 0
1 2 3 4 5 6 ... 13 14

Sommario

Pagina 1 - INSTALLATION MANUAL

835959-UIM-B-0413R-410A OUTDOOR SPLIT-SYSTEM HEAT PUMPMODELS: 14.5 SEER - YHJF/THJF/THGF605 TONS – 1 PHASEINSTALLATION MANUAL®LIST OF SECTIONSGENERAL

Pagina 2

835959-UIM-B-041310 Johnson Controls Unitary ProductsSECTION VI: WIRING DIAGRAM FIGURE 10: Wiring Diagram - Single Phase - 14.5 SEER - 5 Ton

Pagina 3 - LIQUID LINE

835959-UIM-B-0413Johnson Controls Unitary Products 11NOTES

Pagina 4 - SECTION IV: TXV INSTALLATIONS

835959-UIM-B-041312 Johnson Controls Unitary ProductsSECTION VII: START UP SHEETHeat Pump and Supplementary Heat Start-Up Sheet Proper start-up is cr

Pagina 5

835959-UIM-B-0413Johnson Controls Unitary Products 13Supply static after indoor coil (in w.c.")Return Static (in w.c.") before filterTotal E

Pagina 6

Subject to change without notice. Published in U.S.A. 835959-UIM-B-0413Copyright © 2013 by Johnson Controls, Inc. All rights reserved. Supersedes: 835

Pagina 7

835959-UIM-B-04132 Johnson Controls Unitary ProductsRequirements For Installing/Servicing R-410A Equipment• Gauge sets, hoses, refrigerant containers,

Pagina 8 - SECTION VIII: SYSTEM START-UP

835959-UIM-B-0413Johnson Controls Unitary Products 3GROUND INSTALLATIONThe unit may be installed at ground level on a solid base that will notshift or

Pagina 9 - MAINTENANCE

835959-UIM-B-04134 Johnson Controls Unitary ProductsPRECAUTIONS DURING BRAZING SERVICE VALVEPrecautions should be taken to prevent heat damage to serv

Pagina 10 - SECTION VI: WIRING DIAGRAM

835959-UIM-B-0413Johnson Controls Unitary Products 56. Install the TXV equalizer line into the vapor line as follows:a. Select a location on the vapor

Pagina 11 - 835959-UIM-B-0413

835959-UIM-B-04136 Johnson Controls Unitary ProductsFor additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” docu

Pagina 12 - SECTION VII: START UP SHEET

835959-UIM-B-0413Johnson Controls Unitary Products 7 FIGURE 7: Thermostat Wiring – Two-Stage Heat Pump - Variable Speed Air Handler HP 27C Two Stage H

Pagina 13

835959-UIM-B-04138 Johnson Controls Unitary ProductsCFM SELECTION BOARD SETTINGSFor proper system operation the CFM Selection Board jumpers must beset

Pagina 14 - Comments Section

835959-UIM-B-0413Johnson Controls Unitary Products 9SECTION V: INSTRUCTING THE OWNERAssist owner with processing warranty cards and/or online registra

Commenti su questo manuale

Nessun commento